• Saves Water

  • Eliminates Water Hammer

  • Installs Easily Without Tools

  • Cleans the Tank

User rated 5/5 drops

The HydroClean Fill Valve was very easy to install and set up. It works very well in conjunction with the dual flush valve also installed in my 30 year old Commode. Brought my toilet up to 21st century operation.

Joylene, Nebraska

HydroWorks HWK230 Repair Kit

HydroWorks® Toilet Repair Kit
HWK230

  • Kit includes the HydroWorks HWK210 Toilet Fill Valve and the HydroForce Adjustable Flapper HFL190.
     

There are no special skills required to install this product. If water line or toilet appear to be leaking after installation, you should call a plumber immediately.

Fill Valve Installation

Shut water off, flush toilet to empty tank, and remove old toilet fill valve.

Install Valve with Rubber Washer seated as shown above. Nozzle should point back and right within tank.

Our Smart Nut® should only be hand tightened and should make 1-3 audible clicks to signal it is tight. Wings are designed to bend if Smart Nut is overtightened preventing leaks and cracking.

Engage the Float Lock to shut off water to Valve.

Turn upper Valve Body clockwise 1/4 turn, then adjust valve up or down to proper height.

Adjust Valve height so that top of Cap is even with top of tank. This height should allow the final Float adjustment to be achieved with Thumb Screw. Lock valve into place by turning Upper Body counterclockwise.

If overflow tube has a cap remove it and discard before installing Refill Tube.

Install Refill Tube. Attach Cip to overflow tube. Trim tubing to size to prevent kinking and install tubing onto the Mini-Valve Refill Tube Port

NOTE: Refill Tube must be positioned above overflow tube. DO NOT INSERT REFILL TUBING DOWN OVERFLOW PIPE. This improper installation violates plumbing code and could result in a leak.

Determine type of water supply line that you have. Do not use plumber’s putty to seal fittings.

Turn on water and run bath tub to flush out debris. When water is clear, disengage Float Lock to fill tank. This will prevent debris from plugging up aerators or Valve.

A Thumb Screw is provided for fine tune adjustments to float. Proper water level should be indicated inside tank or 1/2" to 1" below overflow tube.

Flapper Instalation